From b7497b5a99f54ab8dcda5b14a308385b2fb03d8d Mon Sep 17 00:00:00 2001 From: Hao Yu Date: Mon, 23 Feb 2026 01:03:31 +0800 Subject: [PATCH] hwmon: (aht10) Fix initialization commands for AHT20 According to the AHT20 datasheet (updated to V1.0 after the 2023.09 version), the initialization command for AHT20 is 0b10111110 (0xBE). The previous sequence (0xE1) used in earlier versions is no longer compatible with newer AHT20 sensors. Update the initialization command to ensure the sensor is properly initialized. While at it, use binary notation for DHT20_CMD_INIT to match the notation used in the datasheet. Fixes: d2abcb5cc885 ("hwmon: (aht10) Add support for compatible aht20") Signed-off-by: Hao Yu Link: https://lore.kernel.org/r/20260222170332.1616-3-haoyufine@gmail.com Signed-off-by: Guenter Roeck --- drivers/hwmon/aht10.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-) diff --git a/drivers/hwmon/aht10.c b/drivers/hwmon/aht10.c index 007befdba977..4ce019d2cc80 100644 --- a/drivers/hwmon/aht10.c +++ b/drivers/hwmon/aht10.c @@ -37,7 +37,9 @@ #define AHT10_CMD_MEAS 0b10101100 #define AHT10_CMD_RST 0b10111010 -#define DHT20_CMD_INIT 0x71 +#define AHT20_CMD_INIT 0b10111110 + +#define DHT20_CMD_INIT 0b01110001 /* * Flags in the answer byte/command @@ -341,7 +343,7 @@ static int aht10_probe(struct i2c_client *client) data->meas_size = AHT20_MEAS_SIZE; data->crc8 = true; crc8_populate_msb(crc8_table, AHT20_CRC8_POLY); - data->init_cmd = AHT10_CMD_INIT; + data->init_cmd = AHT20_CMD_INIT; break; case dht20: data->meas_size = AHT20_MEAS_SIZE;